Pool steps and ladders: types, standards and safety
The way into the pool is a safety feature, not an extra. Below are the specific dimensions from the standard, the difference between the requirements for public and domestic pools, A2 or A4 stainless steel and the slip-resistance classes by surface.

The way into the pool is a safety feature, not an extra. The European standard for the equipment of public pools (EN 13451-2) requires a step height of 230–300 mm and the same for all steps, a ladder width of 450–600 mm, a handrail cross-section of 25–50 mm, and the top step level with the pool edge. Everything that leads into the water must have the strictest slip-resistance class – C.
Below is the breakdown that Croatian articles on this subject lack: concrete dimensions from the standard, the difference between the requirements for public and domestic pools, why A4 stainless steel is not a marketing label but a number, and which slip-resistance class applies to which surface. For the bigger picture of the project, start with our complete guide to building a pool in Croatia.
What kinds of pool entry are there?
In practice there are three solutions: built-in steps formed in the shell itself (Roman, corner, straight), stainless steel ladders fixed to the pool edge, and portable ladders for above-ground pools. All three do the same job, but they differ in when they are decided, how much space they take and what they cost to maintain.
This section is the expert judgement of the Flusso team, based on completed projects, not a quotation from a standard. Across the 800–1,000 pools we have built, the pattern is consistent: people love built-in steps for their looks and comfort, and underestimate how much area they take away. Corner and integrated designs save space because they sit in the corner of the shell and do not intrude on the swimming area – in an 8 × 4 m pool that is the difference between a pool you swim in and a pool you stand in.
| Type of entry | Advantages | Drawbacks | When it is decided |
|---|---|---|---|
| Built-in steps in the shell (Roman, straight) | The most comfortable entry, safe for children and the elderly, a place to sit in the water | Take away swimming area, make the lining more expensive (more curves and edges), an irreversible decision | Before the shell is concreted |
| Corner / integrated steps | Save space, do not intrude on the swimming area, keep the comfort of a built-in entry | Narrower stepping area, more demanding lining work in the corner | Before the shell is concreted |
| Stainless steel ladders (fixed into the edge) | Take nothing from the swimming area, can be added later, can be dismantled in winter | Steeper entry, less suitable for small children and the less mobile, the quality of the stainless steel determines their lifespan | Can also be done after the shell is built |
| Portable ladders (above-ground pools) | No installation; removing the ladder prevents access to the pool | Least stable, need a flat and firm base, not a solution for an in-ground pool | Any time |
We build concrete pools only, so this article deals with entries to go with a reinforced-concrete shell. If you are still deciding on the type of pool, we have compared them in the article on an in-ground or above-ground pool.
What does the standard prescribe for steps and ladders?
There is a Croatian standard that regulates this: HRN EN 13451-2:2020, ‘Swimming pool equipment – Part 2: Additional specific safety requirements and test methods for ladders, stepladders and handle bends’. It was published on 31 July 2020 and is in force. It sets the dimension ranges that every pool entry should respect.

| Element | Requirement from EN 13451-2 | What it means in practice |
|---|---|---|
| Step height | 230–300 mm, and must be the same for all steps | The foot remembers the rhythm of the steps; any step that deviates is a place to fall |
| Tread alignment | Front edges vertically aligned, tolerance ± 10 mm | Steps must not ‘wander’ out of line with one another in plan view |
| Ladder width | 450–600 mm | Anything narrower does not give a stable footing for both feet |
| Top step | Level with the pool edge | Getting out of the water without a ‘hidden’ half-step at the end |
| Handrail | At least one; for widths over 1,200 mm another one, at least 600 mm apart | Wide Roman steps need two handrails, not one in the middle |
| Gripping cross-section | 25–50 mm | A wet child’s hand must be able to close around the tube; anything thicker cannot be gripped |
Source: Croatian Standards Institute, HRN EN 13451-2:2020, dimensional requirements according to EN 13451-2:2015+A1:2020. The standard does not prescribe the number of steps – that is determined by the depth of the pool and the chosen step height.
Does that standard also apply to my pool in the garden?
Not directly. EN 13451 is written for pools for public use – hotels, campsites, sports facilities, public baths. For domestic pools another standard applies: EN 16582, of which Part 1 is general, Part 2 covers in-ground pools and Part 3 above-ground pools with a water depth greater than 400 mm.
That does not mean there are no requirements for a private pool. Clause 5 of EN 16582-1 is devoted precisely to access to the pool (‘means of access’): slip resistance, crushing and entrapment hazards, dimensions and load capacity of ladders, lateral stability, submerged steps and handrails. Annex C prescribes test methods for entrapment of the head and neck, fingers, and feet and hands – exactly the scenarios that happen with children at the entry to a pool.
The dimensions from EN 13451-2 are therefore not mandatory for your private pool, but they are the best available reference for good practice. When we design built-in steps, we stay within those ranges because they are written for public pools, where the load is incomparably greater than on a domestic pool. For a private pool it is a free choice – but a choice that costs nothing.
The same logic applies to Croatian regulation. Ordinance NN 59/2020, Art. 9, para. 1, requires the floors of swimming pool facilities to be slip-resistant, but under Art. 2 it does not apply to pools owned by private individuals that are not intended for public use. There is no obligation; there is also no reason to behave differently from the profession.
How slip-resistant must a step be?
For everything that leads into the water, slip-resistance class C is required – a barefoot class with an angle of inclination greater than 24°, the strictest that exists. According to DGUV Information 207-006, class C is required for ladders and steps leading into the water, sloping pool edges and ramps beside the pool with a slope over 6%.

The pool edge and surround require the milder class B (≥18°), which also covers showers, overflow channel covers and ladders and steps outside the pool. Dry barefoot areas – changing rooms, saunas – require class A (≥12°). The reason for the strictest class precisely on the step into the water is banal: it is the only surface on which a person is at the same time barefoot and wet, puts their whole weight on one leg and cannot see where they are stepping.
Classes A/B/C are measured with the soap solution method and a barefoot tester (DIN 51097, now EN 16165, Annex A). They are not the same thing as R-ratings (R9–R13), which are measured with oil and in footwear, and cannot be converted into one another. If someone offers you an ‘R11 tile for steps’, that is not an answer to the question about class C.
We cover this in detail in the article on ceramics and tiles for pools.
A2 or A4 stainless steel – which to choose for pool ladders?
The difference is one element: molybdenum. According to EN ISO 3506, A2 (approximately AISI 304) has 15–20% chromium and 8–19% nickel, but no specified molybdenum. A4 (approximately AISI 316) has 16–18.5% chromium, 10–15% nickel and 2–3% molybdenum. Molybdenum is what gives the material resistance to pitting corrosion from chlorides.

| Designation | Chromium | Molybdenum | Nickel | PREN |
|---|---|---|---|---|
| A2 (≈ AISI 304) | 15–20 % | not specified | 8–19 % | 17.5–20.8 |
| A4 (≈ AISI 316) | 16–18.5 % | 2–3 % | 10–15 % | 23.1–28.5 |
Data: PREN is calculated by the formula PREN = Cr + 3.3 × Mo + 16 × N and measures resistance to pitting corrosion from chlorides. A higher number means greater resistance. That is why A4 is not a marketing label but a measurable difference in chemical composition. Source: British Stainless Steel Association.
A fair nuance, since it is never mentioned in sales copy: according to the Australian Stainless Steel Development Association (ASSDA), both 304 and 316 are satisfactory for parts that are permanently submerged or regularly rinsed. The real risk is not the water but the atmosphere of an indoor pool, where chlorides condense and deposit on parts that nobody rinses. So: a ladder on an outdoor pool that is constantly in the water will not fall apart because it is A2.
Why do we recommend A4 anyway? Because of the water chemistry we install in practice. For pools up to about 100 m³ we handle disinfection with salt electrolysis – and the most popular size, 8 × 4 × 1.5 m, holds 48 m³ and falls neatly within that range. Salt electrolysis means chlorides permanently present in the water and on the splash zone of the pool edge. With a price difference that is small on one set of ladders, and a difference in PREN that is not, A4 is simply the more rational choice.
As a reference value, Astralpool ‘Easy Access’ ladders are made of AISI-316, with a handrail diameter of 43 mm and a width of 500 mm, in accordance with EN 13451-1 and EN 13451-2, in three- and four-step versions. A 43 mm handrail and a 500 mm width fall exactly within the ranges from the standard – 25–50 mm and 450–600 mm respectively. That is a good test when you compare quotes: take a tape measure and check.
How to make a pool safe for children?
The entry is the most important point, but not the only one. According to the World Health Organization, about 300,000 people drown worldwide every year, almost a quarter of them children under five, and drowning is the fourth leading cause of death in the 1–4 age group. Among the measures the WHO recommends, fencing off pools is expressly listed.
Croatian data: according to the Croatian Institute of Public Health (HZJZ), between 2014 and 2023 769 people died from drowning in Croatia, of whom 47 were children and young people up to the age of 19; in 2023 alone 68 people. The HZJZ recommends that free access to pools and water tanks be prevented.
In practice, from our perspective: built-in steps with an equal step height, a handrail and class C give a child and an elderly person a controlled way in and out. A ladder does not – it demands arm strength and turning your back to the water. If the household includes small children or someone with limited mobility, built-in steps are not an aesthetic choice but a functional one.
Built-in steps or stainless steel ladders – how to decide?
Answer four questions and the decision more or less writes itself.
- Who will use the entry most often? If it is children, parents with children or older members of the household – built-in steps. If it is adult swimmers – ladders are quite sufficient.
- How much swimming area do you have left? In pools of 8 × 4 m and smaller, steps across the full width take away a noticeable part of the length; a corner design keeps the comfort without eating into the swimming length.
- What is the disinfection regime? Salt electrolysis means permanent chlorides – choose A4 on everything metallic, including the handrails of built-in steps.
- What stage of the project are you at? This is a question with a deadline.
The deadline people miss: built-in steps are decided before the shell is concreted. After that they cannot be added – they are part of the reinforced-concrete structure. Stainless steel ladders can be installed later. If you are still not sure what kind of entry you want, decide before the formwork goes to the site, because that is the one point at which the decision costs nothing.
The effect on price goes through the lining, not the structure: built-in steps mean more edges, curves and lining cuts, plus a slip-resistant version on the treads. How this fits into the overall budget is broken down in the example of the price of an 8 × 4 m pool. Ladders and overflow gratings are in the pool surroundings category in our range.
Next step
If you are at the design stage, settle the entry before the formwork layout is decided: the type of entry, the step height within 230–300 mm, the position of the handrail and the slip-resistance class on the treads. These are four decisions that cannot be changed later without demolition. If you already have a pool and are thinking about ladders, measure the width of the edge and the thickness of the handrail and compare them with the ranges in the standard before you order anything.
We work from Makarska to Zadar and discuss the pool entry at the design stage, not at the end of the build. Send us an enquiry with the pool dimensions and who will use it – we typically answer within 24 hours.
Frequently asked questions
According to EN 13451-2 the step height is 230–300 mm and must be the same for all steps, the front edges of the treads must be vertically aligned with a tolerance of ±10 mm, the ladder width is 450–600 mm, and the top step must be level with the pool edge. The standard does not prescribe the number of steps or the depth of the tread – the number of steps follows from the depth of the pool and the chosen step height.
Not directly. EN 13451 is written for pools for public use, and for domestic pools EN 16582 applies – Part 1 general, Part 2 for in-ground pools, Part 3 for above-ground pools with a water depth over 400 mm. Clause 5 of EN 16582-1 is devoted to access to the pool, and Annex C to testing for entrapment of the head, fingers and feet. The dimensions from EN 13451-2 remain a useful reference for good practice.
Class C, with an angle of inclination greater than 24° – the strictest barefoot class. According to DGUV Information 207-006, class C is required for ladders and steps leading into the water, sloping pool edges and ramps with a slope over 6%. The pool edge and surround require class B (≥18°), and dry barefoot areas such as changing rooms class A (≥12°). The R-ratings from DIN 51130 are measured by a different method and are not a substitute.
For a pool with salt electrolysis – yes. A4 (≈ AISI 316) contains 2–3% molybdenum and has a PREN of 23.1–28.5, against 17.5–20.8 for A2 (≈ AISI 304), which means greater resistance to pitting corrosion from chlorides. In fairness, ASSDA states that both 304 and 316 are satisfactory for permanently submerged or regularly rinsed parts; the greatest risk comes from the atmosphere of an indoor pool.
Yes. Stainless steel ladders are fixed into the pool edge and can be added after the shell is finished, and even removed over the winter. Built-in steps cannot – they are part of the reinforced-concrete structure and are decided before concreting. That is the most common irreversible decision that owners fail to consider in time.