Dual Link is an accessory for the EXO iQ / Magnapool IQ device that enables measurement and adjustment of pH and ORP values. The values are measured with probes, and the pH is adjusted by dosing the acid with a peristaltic pump.
- Dual Link performance depends on the performance of the TRi Expert device.
- pH measurement range: 0.0 – 12.0 pH
- ORP measurement range: 100 – 1000 mV
- Calibration of the pH probe with the supplied pH 4.00 and pH 7.00 solution and the ORP probe with a 468 mV solution
- Peristaltic pump can discharge 1.2 l/h